Victaulic Vortex™ 1500 Fire Suppression System

FeaturesApplicationsOperation/DescriptionsPerformance Analysis
  • Can effectively be applied in total flooding fire suppression applications in the following areas: Industrial machine paces such as
  • — Power generation plants
  • — Turbine enclosures
  • — Automotive manufacturing
  • — Steel foundry 
  • — Flammable liquids storage 
  • — Data centers
  • — Museums 
  • — Libraries  
  • — Mining facilities
  • Touchscreen interface provides a simplified view into the operational aspects of the system

The Victaulic Vortex 1500 Fire Suppression System can effectively be applied in total flooding fire suppression applications in the following areas:

  • Industrial machine spaces such as power generation plants, turbine enclosures, automotive manufacturing, steel foundry 
  • Flammable liquids storage 
  • Data centers, museums, libraries
  • Mining facilities

The system incorporates an open architecture design and is fully compatible with automatic hazard detection systems and is adaptable for remote manual activation if required. A system installation and maintenance manual is available containing information on system components and procedures concerning design, operation, inspection, maintenance and recharge. The Victaulic Vortex 1500 system is particularly useful for suppressing fires in hazards where an electrically non-conductive medium is essential or desirable, where clean-up of other agents present a problem, where room integrity is not achievable or where the hazard is normally occupied and requires a non-toxic agent. The basic system consists of stored nitrogen and either potable or captive water supply, or de-ionized water piping along with single or multiple zone control boxes and system emitters in the hazard area. The suspension of water and nitrogen is distributed and discharged into the hazard area through a network of pipe and emitters. System emitters can be installed in either a pendent or sidewall configuration and are positioned via straight-forward cubic-foot/meter coverage volume requirements.

Water Characteristic Comparison 
  Flow, GPM / LPM Per Emitter, Nozzle or Sprinkle Drop Size, μm Operating Pressure, PSIG Velocity
Agent
Victaulic Vortex Fire Suppression System 0.26 / 0.98 <10 25 / 172.4 High
Intermediate Pressure Water Mist 37 / 140 400 – 1000 350 / 2413.2 High
High Pressure Water Mist ~ 8* / 30.2 50 – 100 1500 – 2500 / 10342.1 – 17236.9 Low
Sprinkler Systems >25 / 94.6 >1000 >20 min / 137.9 Moderate
Inert Gases N/A N/A 2500 / 17236.9 N/A
Halogenated Agents N/A N/A 360 / 2482.1 N/A